Search
Menu
Excelitas PCO GmbH - PCO.Edge 11-24 BIO LB

Plasma Probes Pulp Painlessly

Facebook X LinkedIn Email
LOS ANGELES, Aug. 31, 2009 – For some, nothing is more intimidating than a visit to the dentist’s office, especially when the appointment is for a root canal. The process is painful and can be a drawn-out experience.

Rootcanal1.jpg
Cold plasma emitted from a dental probe disinfects saliva-derived biofilm on an extracted human tooth. When the tooth is placed 5 mm below the tubular device nozzle for 5 min, 99.99 percent of the biofilm within the root canal is removed. (Images courtesy of Dr. Chunqi Jiang)

A routine root canal procedure, or endodontic treatment, involves drilling a hole inside the canal of a tooth to reach infected pulp tissue – where nerve fibers, veins and connective tissue are located. The diseased pulp is removed from the canal, leaving an empty cavity, which, after extensive cleaning with liquid antibiotics, is filled with a flexible plastic material called gutta-percha and then crowned.

However, completely disinfecting a root canal can require two or three return visits to the dentist’s office. To reduce the process to one visit, Dr. Chunqi Jiang of the electrical engineering and electrophysics department at the University of Southern California, and fellow researchers developed a cold-plasma jet that may prevent deposits of bacteria from being left behind, while also relieving pain. Her study was published in the July 2009 issue of IEEE Transactions on Plasma Science.

Replacing the drill

Cold plasma is becoming a staple in surgical procedures because its high-voltage ionized pulses of air or mixtures of oxygen and gases such as argon or helium are noninvasive and cool to the touch. Plasma has benefited those who use coagulation, sterilization and tissue engineering. Applying cold plasma in dental procedures will “help [clinicians] to identify novel therapeutic technologies based on cold plasma for root canal disinfection,” Jiang said.

Jiang designed a plasma dental probe that in one session can rid a root canal of saliva-derived biofilm, a layer of bacteria known to be resistant to antibiotics. The apparatus emits a plasma plume up to 2.5 cm long with a diameter of 3 mm, which fits inside the 2- to 3-cm-long canal. The short, intense electric pulses, which generate 6 kV and 1 kHz at about 100 ns, are low-powered at approximately 1 W and provide a noise- and pain-free method that is safe, with minimum heat.

Rootcanal2.jpg
Scanning electron microscope images reveal the inside of an extracted human tooth. The plasma plume reached and disinfected 1 mm of biofilm from the root canal, while below, biofilm is still present (a). A plasma-treated root canal surface shows open dentinal tubes within the root canal (b).


Excelitas Technologies Corp. - X-Cite Vitae  MR 11/24
To test the plasma jet’s capability, Jiang used the equipment to disinfect the root canal of an extracted human tooth with a substantial layer of biofilm in the canal as observed by a scanning electron microscope. The tooth was placed a few millimeters beneath the tubular device nozzle for 5 min. The dental probe, with a 2-mm-diameter plasma plume, ranged from 15 to 28 mm in length with a gas mixture of helium and 1% dioxygen set at room temperature. Additionally, it applied a voltage of 4 to 8 kV with a flow rate of 1 to 5 liters/min-1.

During plasma treatment, electrons collide with atoms and molecules to initiate high dissociation, excitation and ionization in the plume. The researchers can widen and lengthen the plume to attain greater sterilization depth and surface coverage.

As a result, the plasma dental probe removed 99.99 percent of the saliva-derived biofilm in the tooth. A visible contrast line between the plasma-treated and nonplasma-treated areas was evident.

Don't sweat it

Compared to laser procedures, cold plasma is less expensive and pain-free, and it eliminates the risk of burning a patient’s gums. During testing, to make certain that the plasma did not produce too much heat, temperatures were monitored throughout exposure. The findings revealed that the plasma began at room temperature (22 °C) and increased to 31 °C within the first 30 seconds. Afterward, the temperature increased only gradually, by 0.8 °C per minute, confirming that heat-induced plasma is tolerable for patients undergoing bactericidal treatments.

To further determine what stops biofilm from recurring, Jiang used plasma emission spectroscopy with a monochromator and a photomultiplier tube to investigate the plasma plume and its primary reactive species. What the researchers found was that, compared with excited nitrogen molecules and with helium and nitrogen ions, atomic oxygen is more reactive during emission and is therefore the more likely agent in inactivating bacteria within the canal. Currently, Jiang is measuring concentrations of atomic oxygen while further investigating other plasma bactericidal mechanisms.

Amanda Francoeur
[email protected]




Published: August 2009
Glossary
coagulation
Coagulation refers to the process of transforming a liquid, particularly blood or a solution containing dispersed particles, into a solid or semi-solid state. This term is most commonly associated with blood clotting but can also apply to other processes in chemistry and biology. In the context of blood, coagulation is the complex process by which blood forms clots to stop bleeding. It involves a cascade of events that include: Vasoconstriction: The blood vessels constrict to reduce...
emission spectroscopy
Emission spectroscopy is a technique used to study the emission of electromagnetic radiation (light) by atoms, molecules, or ions when they undergo transitions from excited states to lower energy states. This technique provides valuable information about the energy levels, electronic structure, and chemical composition of the emitting species. Principle of emission: Emission occurs when atoms, molecules, or ions in an excited state return to lower energy states, releasing energy in the form...
monochromator
A monochromator is an optical instrument used to isolate and select a narrow range of wavelengths from a broader spectrum of light. The term monochromator is derived from "monochromatic," meaning consisting of a single color or wavelength. Monochromators are essential tools in spectroscopy, allowing researchers to analyze the spectral characteristics of light sources or materials. monochromator suppliers → The basic principle of a monochromator involves dispersing incoming light...
optical emission spectroscopy
In dry etching, a method of characterizing the composition of solid materials such as metal. Atoms in the OES technique are excited by energy that comes from a spark formed between the sample and an electrode. This energy emits light, which can then be converted into a spectral signal. The intensity recorded at the peaks of this spectral signal produce accurate material composition analysis.
photomultiplier tube
A photomultiplier tube (PMT) is a highly sensitive vacuum tube that detects and amplifies low levels of light. It is widely used in various applications where high sensitivity, fast response times, and low-light detection capabilities are crucial. Photomultiplier tubes are particularly valuable in scientific research, medical diagnostics, and industrial instrumentation. Key features and principles of PMTs include: Photoelectric effect: The operation of a photomultiplier tube is based on the...
photonics
The technology of generating and harnessing light and other forms of radiant energy whose quantum unit is the photon. The science includes light emission, transmission, deflection, amplification and detection by optical components and instruments, lasers and other light sources, fiber optics, electro-optical instrumentation, related hardware and electronics, and sophisticated systems. The range of applications of photonics extends from energy generation to detection to communications and...
plasma
A gas made up of electrons and ions.
scanning electron microscope
A scanning electron microscope (SEM) is a powerful imaging instrument used in scientific research, materials characterization, and various industrial applications. Unlike traditional optical microscopes, which use visible light to magnify and image specimens, SEMs use a focused beam of electrons to generate high-resolution images of a sample's surface. scanning electron microscope suppliers → The basic principle of operation involves focusing a beam of electrons onto the...
atmospheric pressure plasmaatomic oxygenbacteriabactericidal treatmentBasic SciencebiofilmbiomedicineBiophotonicsChunqi Jiangclinicianscoagulationcoaxial tubular devicecold plasmacold-plasma jetdental probedentistdisinfectantemission spectroscopyEndodontic treatmentinfectionionized gasliquid antibioticsMicroscopymonochromatorNews & Featuresoptical emission spectroscopypain-freephotomultiplier tubephotonicsplasmaplasma dental probeplasma plumePMTResearch & Technologyroot canalsaliva-derived biofilmscanning electron microscopesterilizationsurgerytissue engineeringUniversity of Southern California