Search
Menu
Teledyne DALSA - Linea HS2 11/24 LB

Unidirectional Imaging Enables Asymmetric Visual Info Processing

Facebook X LinkedIn Email
Traditional imaging systems are bidirectional — if a camera can see a person, the person can see a camera. Researchers at UCLA recently developed a new type of imaging technology that could revolutionize how visual information is captured and processed: unidirectional imaging. By allowing images to be formed in only one direction, this technology provides an efficient and compact method for asymmetric visual information processing and communication.

Unidirectional imaging is designed to form images from one FOV to another, while blocking image formation in the reverse direction. This means that images are only formed from FOV A to FOV B and not the other way around.
Unidirectional imaging technology forms images in only one direction, significantly enhancing imaging efficiency and clarity. These imagers work effectively under partially coherent light, achieving high-quality imaging from one field of view to another, while blocking reverse image formation. Courtesy of Ozcan Lab/UCLA.
Unidirectional imaging technology forms images in only one direction, significantly enhancing imaging efficiency and clarity. These imagers work effectively under partially coherent light, achieving high-quality imaging from one FOV to another, while blocking reverse image formation. Courtesy of Ozcan Lab/UCLA.

The Ozcan Research Group at UCLA, led by Professor Aydogan Ozcan, demonstrated that these imagers work exceptionally well under partially coherent light, which is light that has some degree of phase correlation. They achieved high-quality imaging in the forward direction (point A to point B) with high power efficiency, while the reverse direction (point B to point A) showed distorted images and much lower power efficiency. This selective imaging capability is made possible by a set of spatially engineered asymmetric linear diffractive layers that are optimized for partially coherent illumination.

Zurich Instruments AG - Challenge Us 10/24 MR

Their research revealed that when the imagers are illuminated by a partially coherent beam with a phase correlation length of at least 1.5 times the wavelength of light (λ), they perform robustly, showing a clear difference in imaging quality between the forward and backward directions. Even with a smaller correlation length, the imagers still support unidirectional image transmission, though with slightly reduced performance.

These imagers are compact, measuring less than 75 times the wavelength of light in thickness, and are independent of light polarization. They are also compatible with various types of light sources, including broadband radiation, making them versatile for different applications. This makes them particularly useful for asymmetric visual information processing and communication, where controlling the direction of image formation is crucial.

The development of unidirectional imagers marks a significant step forward in imaging technology, offering new possibilities for scientific research and practical applications in fields such as optical communication and visual information processing.

The research was published in Advanced Photonics Nexus (www.doi.org/10.1117/1.APN.3.6.066008).

Published: November 2024
Research & TechnologyImagingunidirectionalimagerasymmetricprocessingoptical communicationAydogan OzcanUniversity of CaliforniaLos AngelesUCLApartially coherentAdvanced Photonics NexusAmericas

We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. By using this website, you agree to the use of cookies unless you have disabled them.