Search
Menu
Bristol Instruments, Inc. - 872 Series LWM 10/24 LB

Photoacoustic Technique Captures Real-Time Anomalies in Microvasculature

Facebook X LinkedIn Email
DOUGLAS FARMER, SENIOR EDITOR
[email protected]

LONDON, Oct. 16, 2024 — By using a laser to generate ultrasound waves that reveal structural changes, photoacoustic tomography (PAT) has shown its value in identifying disease conditions in the microvasculature, the tiny vessels that extend from major veins and arteries. To this point, however, the process has been too slow to capture this information in real time, limiting its value in clinical settings. That is now changing, thanks to a device developed at University College London (UCL) that doctors could potentially hold right in their hands.

Traditionally, PAT scans have required a patient to remain motionless for an extended period of time to prevent blurring, but the UCL scanner enables such images in seconds by measuring ultrasound waves at numerous points simultaneously.
An image of the upper surface of a subject’s tongue, generated with photoacoustic tomography. Courtesy of Paul Beard/University College London.
An image of the upper surface of a subject’s tongue, generated with photoacoustic tomography. Courtesy of Paul Beard/University College London.

“Some previous PAT scanners that use piezoelectric detectors arrays were fast but image quality was limited due to the non-ideal acoustic characteristics of piezoelectric detectors,” said Paul Beard, a professor in the UCL Department of Medical Physics and Biomedical Engineering. “We developed our optical sensor-based system some years ago which gave better image quality but it was slow (5 mins for a 3D image) precluding clinical use.”

The scanner was built for the current study with components including an optical parametric oscillator excitation laser pulses — delivered through optical fiber, which generated the ultrasound waves — and a Fabry-Perot ultrasound scanner to generate a map of the effects they revealed. The speed to acquire images is reduced by using high pulse repetition frequency lasers, parallelizing the readout and compressed sensing, said Beard.

PI Physik Instrumente - Space Qualified Steering MR LW 12/24

In their study, the group used the scanner during preclinical examination on 10 patients with type-2 diabetes, rheumatoid arthritis, and breast cancer, along with seven healthy volunteers. In those with diabetes, deformation in the blood vessels in the feet were clearly identified. They also captured the inflammation present during breast cancer. They obtained detailed images from the fingertip and wrist, and demonstrated its utility for the tongue as well (see accompanying image).

“We demonstrated dynamic capability in the fingertip and wrist, but in principle this could be done on any part of the body,” Beard said.

Researchers noted that the PAT scanner has significant implications for patients suffering from peripheral vascular disease, in which blood vessels narrow or become blocked, especially in the hands or feet. Causes range from smoking to elevated cholesterol. Ultrasound is often used in diagnosis but it has difficulty capturing the flow present or lacking in smaller blood vessels.

Beard said the next step will be to draw from a larger study cohort. “The group will be drawn from hospital patients with arthritis and peripheral vascular disease in the near future,” he said. “We also plan to evaluate the device as a tool for guiding cancer and plastic surgery.”

The UCL team’s research was supported by Cancer Research UK, the Engineering & Physical Sciences Research Council, Wellcome, the European Research Council, and the National Institute for Health Research University College London Hospitals Biomedical Research Centre.

The research was published in Nature Biomedical Engineering (www.doi.org/10.1038/s41551-024-01247-x).

Published: October 2024
Glossary
photoacoustic
Photoacoustic refers to the generation of acoustic (sound) waves following the absorption of light (usually laser pulses) by a material. This phenomenon occurs when light energy is absorbed by a material, leading to localized heating and subsequent thermal expansion, which generates pressure waves (sound waves) that can be detected using ultrasonic sensors. The photoacoustic effect is utilized in various scientific and medical applications, including: Photoacoustic imaging (PAI): A...
optical parametric oscillator
A laser-pumped crystal with nonlinear optical properties inside of an optical resonator in which the output generates coherent light whose output can be tuned continuously over a variety of infrared and visible wavelengths. The OPO generates a short wavelength component called the signal and a longer wavelength component called the idler. Conservation of energy dictates that the sum of the photon energy of the signal and that of the idler equals the original pump photon energy.
optical fiber
Optical fiber is a thin, flexible, transparent strand or filament made of glass or plastic used for transmitting light signals over long distances with minimal loss of signal quality. It serves as a medium for conveying information in the form of light pulses, typically in the realm of telecommunications, networking, and data transmission. The core of an optical fiber is the central region through which light travels. It is surrounded by a cladding layer that has a lower refractive index than...
Research & TechnologyphotoacousticImagingPhotoacoustic tomographyultrasoundmicrovasculaturecirculatoryoptical parametric oscillatorLasersoptical fiberdiagnosticsblood vesselsNature Biomedical EngineeringUniversity College LondonEurope

We use cookies to improve user experience and analyze our website traffic as stated in our Privacy Policy. By using this website, you agree to the use of cookies unless you have disabled them.