Register
Sign In
Suppliers
Products
Categories
Handbook
Dictionary
Careers
Resources
Photonics Spectra
BioPhotonics
Vision Spectra
Virtual Events & Summits
Educational Institutions
Add/Update Your Listing
Exhibitor Listing Portal
Become an Exhibitor
Buyers' Guide Print Edition
Marketplace Help
Subscribe
Advertise
Suppliers
Products
Categories
Handbook
Dictionary
Careers
Resources
Photonics Spectra
BioPhotonics
Vision Spectra
Virtual Events & Summits
Educational Institutions
Add/Update Your Listing
Exhibitor Listing Portal
Become an Exhibitor
Buyers' Guide Print Edition
Marketplace Help
Register
Sign In
Photonics Marketplace
Suppliers
Products
Handbook
Institutions
Dictionary
Show Filters
Hide Filters
Products by Category
< All Categories
< Optomechanics & Positioning
< Galvanometers
2 Axis
Applications
Additive Manufacturing
Biomedical/Medical
Laser Cutting
Laser Marking
Laser Welding
Micromachining
Max. Beam Diameter
-
µm
mm
cm
dm
m
Max. Scan Angle X (degrees)
-
Max. Scan Angle Y (degrees)
-
Small Step Response (µs)
-
Repeatablility (µrad)
-
Linearity (%)
-
Overall Height (no mirror)
-
mm
cm
Weight
-
g
kg
Key Suppliers
Novanta Photonics, Precision Medicine & Manufacturing
Aerotech Inc.
SCANLAB GmbH
18 products
Galvanometers: 2 Axis
Clear All Filters x
Optomechanics & Positioning x
Galvanometers x
2 Axis x
AGV-XPO High-Dynamic Laser Scan Head
Aerotech Inc.
Max. Scan Angle X (degrees):
20
Max. Scan Angle Y (degrees):
20
excelliSCAN
SCANLAB GmbH
Max. Scan Angle X (degrees):
0.35
Repeatablility (µrad):
0.4
Weight:
7kg
intelliSCANse
SCANLAB GmbH
MOVIA 2-Axis Laser Scan Head
Novanta Photonics, Precision Medicine & Manufacturing
Aperture:
10 mm
Repeatability:
< 3.5 µrad
Scan Angle:
± 20°
VERSIA 2-Axis Hybrid Laser Scan Head
Novanta Photonics, Precision Medicine & Manufacturing
Aperture:
14 mm
Repeatability:
< 2 µrad
Scan Angle:
± 21°
AGV-HP(O)
Aerotech Inc.
Max. Beam Diameter:
30mm
Max. Scan Angle X (degrees):
40
Max. Scan Angle Y (degrees):
40
Small Step Response (µs):
270
Repeatablility (µrad):
0.4
Linearity (%):
0.005
Long-Term Drift:
10 µrad / 12 hr
Max. Positioning Speed:
75 m/s
Processing Speed:
5 m/s
AGV-SPO
Aerotech Inc.
Max. Beam Diameter:
35mm
Max. Scan Angle X (degrees):
20
Max. Scan Angle Y (degrees):
20
Small Step Response (µs):
700
Repeatablility (µrad):
0.6
Linearity (%):
0.005
Accuracy:
50 µrad pk-pk
Beam Aperture:
14 mm
Dither:
0.3 µrad
intelliSCAN IV
Scanlab America Inc.
Dual-Axis Galvanometer Scan Heads
Thorlabs Inc.
Max. Beam Diameter:
45mm
Max. Scan Angle X (degrees):
22.5
Max. Scan Angle Y (degrees):
22.5
Small Step Response (µs):
1200
Repeatablility (µrad):
10
Linearity (%):
99.9
Control Electronics:
Analog Servo Amplifiers
Gain Drift:
50 ppm/°C
Mirror Substrate:
Fused Silica/SiC/Si
GM-1015 Digital Encoder Galvano Scanner
Canon U.S.A. Inc., Industrial Products Div.
Max. Beam Diameter:
15mm
Max. Scan Angle X (degrees):
20
Max. Scan Angle Y (degrees):
20
Small Step Response (µs):
390
Repeatablility (µrad):
3
Overall Height (no mirror):
88mm
GM-1005 Digital Encoder Galvano Scanner
Canon U.S.A. Inc., Industrial Products Div.
Max. Beam Diameter:
5mm
Max. Scan Angle X (degrees):
30
Max. Scan Angle Y (degrees):
30
Small Step Response (µs):
200
Repeatablility (µrad):
5
Overall Height (no mirror):
58mm
GM-1020 Digital Encoder Galvano Scanner
Canon U.S.A. Inc., Industrial Products Div.
Max. Beam Diameter:
30mm
Max. Scan Angle X (degrees):
20
Max. Scan Angle Y (degrees):
20
Small Step Response (µs):
540
Repeatablility (µrad):
3
Overall Height (no mirror):
106.2mm
excelliSCAN
Scanlab America Inc.
Repeatablility (µrad):
0.4
Overall Height (no mirror):
158.5cm
Weight:
7kg
Fast Scanning Mirror
Optics for Hire
Max. Beam Diameter:
5.5mm
Max. Scan Angle X (degrees):
15
Max. Scan Angle Y (degrees):
15
Overall Height (no mirror):
35mm
Resonant Frequency:
20 – 80 Hz
GM-1010 Digital Encoder Galvano Scanner
Canon U.S.A. Inc., Industrial Products Div.
Max. Beam Diameter:
10mm
Max. Scan Angle X (degrees):
20
Max. Scan Angle Y (degrees):
20
Small Step Response (µs):
280
Repeatablility (µrad):
3
Overall Height (no mirror):
78mm
Saturn 9B
ScannerMAX
Max. Beam Diameter:
10mm
Max. Scan Angle X (degrees):
110
Max. Scan Angle Y (degrees):
110
Small Step Response (µs):
300
Repeatablility (µrad):
5
Linearity (%):
99.9
Saturn 5B
ScannerMAX
Max. Beam Diameter:
6mm
Max. Scan Angle X (degrees):
110
Max. Scan Angle Y (degrees):
110
Small Step Response (µs):
120
Repeatablility (µrad):
5
Linearity (%):
99.9
Saturn 1B
ScannerMAX
Max. Beam Diameter:
4mm
Max. Scan Angle X (degrees):
110
Max. Scan Angle Y (degrees):
110
Small Step Response (µs):
75
Repeatablility (µrad):
5
Linearity (%):
99.9
Galvanometers: 2 Axis Products
Need Help?
Explore Our Content
News
Features
Latest Products
Webinars
White Papers
All Things Photonics Podcast
Photonics Spectra
Now
Videos
Our Summits & Conferences
Industry Events
Bookstore
Join Our Community
Subscribe
Advertise
Become a member
Sign in
Contribute a Feature
Suggest a Webinar
Submit a Press Release
Mobile Apps
About Us
Our Company
Our Publications
Contact Us
Career Opportunities
Teddi C. Laurin Scholarship
Terms & Conditions
Privacy Policy
California Consumer Privacy Act (CCPA)
©2024 Photonics Media
100 West St.
Pittsfield, MA, 01201 USA
[email protected]
We use cookies to improve user experience and analyze our website traffic as stated in our
Privacy Policy
. By using this website, you agree to the use of
cookies
unless you have disabled them.