A new weapon shines light on malaria
Hank Hogan
In war, it is important to know your enemy. The same is true when fighting disease,
especially a deadly one that has grown resistant to drugs.
Researchers at Georgetown University in Washington
have developed a customized spinning disk confocal microscope that enables them
to image — with enough resolution for measurement of features — live
malarial parasites wiggling inside human red blood cells. This information could
provide a valuable tool in combating malaria.
“This helps us understand drug
resistance and aids design of new drugs and other therapies,” said Paul D.
Roepe, leader of the research team. Roepe, professor of chemistry and of biochemistry,
cellular and molecular biology, is co-director of the university’s Center
for Infectious Disease. He noted that drug-resistant malaria kills about a million
people a year worldwide. Thus, there is tremendous interest in learning more about
how antimalarial drugs work so that new drugs can be developed.
The nature of malaria makes obtaining
this information a challenge. The disease, widespread in the tropics, debilitates
millions of people annually worldwide. It is caused by parasites that are mostly
transmitted by mosquitoes. The parasites invade blood cells, eventually consuming
them and causing fever, anemia and even death.
Molecular investigational methods require
the use of low-density human blood cultures, which are time-consuming and expensive
to produce. So researchers are developing new techniques, including optical ones.
Unfortunately, imaging the parasites
is challenging because they move inside their host cells, resulting in blurred images
when acquired at high resolution via conventional laser scanning confocal microscopy.
The parasites also have features of interest that are smaller still. Researchers
need the resolution offered by scanning confocal microscopy but at much faster acquisition
times.
The group, therefore, turned to spinning
disk confocal microscopy, which is similar to scanning confocal microscopy in that
it uses a pinhole effect to reject most out-of-focus light. However, instead of
one pinhole, it uses thousands that are on a disk. A second disk bears microlenses
that align with the pinholes on the first disk. The disks spin — synchronized
— resulting in a significant improvement in image-acquisition speed.
Roepe noted that this technique allows
three-dimensional data to be acquired in less than one second, thus eliminating
blurring. That, in turn, improves the ability to reliably quantify certain parameters,
such as the volume of intracellular compartments.
As described in two papers in the Oct.
17 issue of
Biochemistry, the researchers modified a commercial spinning
disk confocal microscope from PerkinElmer of Wellesley, Mass., adding a cooled CCD
camera from Hamamatsu Corp. of Bridgewater, N. J., an argon-krypton laser from Coherent
Inc. of Santa Clara, Calif., and, for fast illumination control, an acousto-optic
tunable filter from Melbourne, Fla.-based Neos Technologies. They added Nikon differential
interference contrast optics, which necessitated a change in the microscope’s
stage to one from Merzhauser. Finally, they used a piezoelectric controller from
Cambridge, Mass.-based Piezo Systems for fast Z-axis movement of the objective.
With this setup, they achieved better
than 250-nm resolution in all three dimensions while completing a full scan in less
than 800 ms.
Other aspects of the technology were
algorithms and a customized dual-processor computer to deblur images and to correct
for axial smearing, thereby improving the quality of the data. Processing the image
files was computationally intensive, with some of the experiments requiring the
handling of hundreds of files and 10 GB of raw data. Roepe said that the size of
the files and the speed with which they were processed was unusual for a microscopy-based
study.
While the technology made the imaging
possible, the application of cell biology techniques ensured that there was something
informative to image. In their investigations, the researchers looked at the development
of the parasites under specific conditions and with particular attributes. To gather
meaningful data, they had to be able to look at more than one parasite at any given
time. “The ability to closely synchronize the parasite cell culture so that
every parasite in the culture is at the same stage of development is also important,”
Roepe said.
They used the techniques and the imaging
technology for several studies of malaria. In one, they quantified the development
of hemozoin, the crystallization of heme released upon hemoglobin digestion in the
parasite, for both drug-sensitive and drug-resistant malaria. They analyzed the
growth of hemozoin in the presence and the absence of chloroquine, one of a family
of drugs that has been the chief line of defense against malaria. Data from other
studies had suggested that such drugs act by inhibiting hemozoin growth in some
fashion, but the exact nature of their effects in vivo was not known.
These high-resolution differential interference contrast images of
hemozoin — the crystallization of heme released upon hemoglobin digestion
in the malaria parasite — were taken at various stages of development of the
parasite. They were taken in less than 100 ms using spinning disk confocal microscopy.
The researchers used chloroquine in
doses large enough to affect the parasites that were sensitive and tracked the rate
of formation of hemozoin over time. Because hemozoin is optically dense, they could
use differential interference contrast, allowing them to use just a few cells in
each experiment — an advantage given the difficulty of culturing the parasites
in bulk.
The measured hemozoin production tracked
known visual criteria, with rapid increases in the beginning and a plateau later.
The researchers found, though, that, in the presence of chloroquine, the production
did not drop until 50 percent of the hemozoin had formed. From that, and the effect
of verapamil, an agent known to reverse chloroquine resistance, they concluded that
the drug’s toxicity was caused by the buildup of the noncrystalline form of
the digestive byproduct. That result agreed with the leading hypothesis about how
chloroquine works.
However, the different strains produced
hemozoin at the same rate and suffered from roughly the same decrease when exposed
to chloroquine — an unforeseen result, according to Roepe. “We initially
expected to see some difference in the rate of hemozoin production for the drug-resistant
versus the drug-sensitive strains of malarial parasites,” he said.
In their second study, the scientists
looked at chemical and volume differences in the digestive vacuole in drug-resistant
malaria, comparing them with the drug-sensitive variety. For the chemistry, they
measured the pH of the two strains and found that the digestive vacuoles of the
drug-resistant variety are more acidic.
For volume measurements, they used
fluorescence imaging, with 488-nm excitation from the laser and the fluorophore
Oregon Green coupled to dextran internalized in the parasite. They calculated the
volume of the vacuole by optically stepping through it in 0.2-μm Z-axis increments
and by processing the acquired data, doing this for 20 or more cells for each strain.
They found that, at maturity, the drug-resistant strains had larger digestive vacuole
volumes than those of the drug-sensitive strains by a factor of about two. One implication
of this, Roepe noted, is that the drug concentration in this subcellular compartment
would be different for resistant malaria, which could be important in the drug resistance
itself.
In this fluorescence-based
image, changes in the volume of the digestive vacuole of the parasite responsible
for malaria are quantified at different times before removal of chloride from the
perfusate flowing over the cells (top), during removal (middle) and after chloride
replacement (bottom). Images courtesy of Paul D. Roepe, Georgetown University.
The researchers are making hemozoin-formation
measurements using different drugs and strains, experimenting with various fluorescent
labels, and developing methods to simultaneously monitor dual- and triple-labeled
cells. On the equipment side, they are developing ratiometric spinning disk confocal
microscopy imaging as well as the ability to acquire differential interference contrast
and fluorescence data at the same resolution from the same cell.
“We should be making fairly substantial
progress on all these fronts over the next year or so,” Roepe said.
LATEST NEWS
- Lightwave Logic Makes Changes to Leadership
Dec 11, 2024
- Ayar Labs Secures $155M from Investors Including AMD, NVIDIA
Dec 11, 2024
- Evosys Adds to Management Team: People in the News: 12/11/24
Dec 11, 2024
- Hyperspectral Satellite Developer Pixxel Raises $24M
Dec 11, 2024
- Solar-Based Synaptic Device Boosts Edge AI Efficiency for Optical Sensing
Dec 11, 2024
- Study Prods Possible Link Between Solar Panels, Building Fires
Dec 10, 2024
- Microscopy Method Supports 3D, Multitargeted Cell Imaging at Nanoscale
Dec 10, 2024
- Microscopy Method Provides Quality Control for Digital Manufacturing
Dec 10, 2024