• Combining the known centering measurement technology integrated in OptiCentric® with the OptiSurf® low coherence interferometer for measuring the air gaps between lens elements and the center thickness of lenses within the optical system
• The cross-interaction allows fast alignment of the lens system, and provides a significant increase of the overall measurement accuracy and detailed manufacturing quality information for comprehensive compliance testing of assembled optics
• Measurement accuracy of centering errors /air spacing and center thickness: 0.1 µm / 1 µm